Pull the implant out using a proper screwdriver, either a manual screwdriver or a ISO screwdriver.
  • Pull the implant out using a proper screwdriver, either a manual screwdriver or a ISO screwdriver.
  • Put into place and partly screw down, continue screwing using the handpiece or the Ratchet P500002 equipped with the large Insert P800000 with the manual screwdrivers: Long manual Screw-driver P600008 for small four-lobed cam implant and Short manual Screw-driver P600011 for small four-lobed cam implant.
  •  Screw-drivers have dot markings serving used as references for directing the cams of the implant while screwing. This should be useful when applying the prosthesis, if we are using an angled abutment.
  • Recommended speed when using the handpiece: 15 to 20 rpm
  • Maximum torque: 40 N. 
  • Remove the cap screw from its housing and screw it onto the implant using the long manual hexagonal screwdriver P600006 or short manual hexagonal screwdriver P600007 in order to have a correct positioning of the implant.

 

  • Pull the implant out using a proper screwdriver, either a manual screwdriver or a ISO screwdriver.
  • Put into place and partly screw down, continue screwing using the handpiece or the Ratchet P500002 equipped with the large Insert P800000 with the manual screwdrivers: Long manual Screw-driver P600008 for small four-lobed cam implant and Short manual Screw-driver P600011 for small four-lobed cam implant.
  •  Screw-drivers have dot markings serving used as references for directing the cams of the implant while screwing. This should be useful when applying the prosthesis, if we are using an angled abutment.
  • Recommended speed when using the handpiece: 15 to 20 rpm
  • Maximum torque: 40 N. 
  • Remove the cap screw from its housing and screw it onto the implant using the long manual hexagonal screwdriver P600006 or short manual hexagonal screwdriver P600007 in order to have a correct positioning of the implant.

 

Content of the pack:
- Threaded implant Grade 4 Ti
- Mounter Grade 5 Ti
CODEPRODUCT NAMEDIAMETER IN MMLENGHTCOLOUR CODEIVA
P114213EASY TAPPING FIXTURE4.213blue4
P114215EASY TAPPING FIXTURE4.215blue4
P114218EASY TAPPING FIXTURE4.218blue4
P114211EASY TAPPING FIXTURE4.211blue4%