PRIMER SR FOUR-LOBED CAM Ø3,75/4,2/4,5

PRIMER SR FOUR-LOBED CAM Ø3,75/4,2/4,5 | fixture dental mounter titanium sinuz lift all-on-four all-on-six

PRIMER SR FOUR-LOBED CAM Ø3,75/4,2/4,5
Ask
Print
Invite a Friend

PRIMER SR FOUR-LOBED CAM Ø3,75/4,2/4,5

Pull the implant out using a proper screwdriver, either a manual screwdriver or a ISO screwdriver.
  • Pull the implant out using a proper screwdriver, either a manual screwdriver or a ISO screwdriver.
  • Put into place and partly screw down, continue screwing with the handpiece or with the ratchet P500002, using the appropriate ISO insert P900000 and the appropriate screwdrivers P500008, long, four-lobed cam, or P500011 short, four-lobed cam.
  • To screw the implant fixture, it is possible to use the ratchet with big insert P800000,  using the manual screwdrivers for three-lobed camP 600008 long, and P600011 short.
  • The cam screwdrivers have dot markings used as references for directing the cams of the implant while screwing. This should be useful when applying the prosthesis, if we are using an angled abutment.
  • Recommended screwing speed: 15/20 rpm.
  • Torque not exceeding 40 Ncm.
  • No irrigation.
  • We recommend removing the cap screw from its housing and screwing it onto the implant using the manual screwdriver with no torque control  P500005/ P600000, to have direct perception of correct positioning of the screw and of its screwing.

 

  • Pull the implant out using a proper screwdriver, either a manual screwdriver or a ISO screwdriver.
  • Put into place and partly screw down, continue screwing with the handpiece or with the ratchet P500002, using the appropriate ISO insert P900000 and the appropriate screwdrivers P500008, long, four-lobed cam, or P500011 short, four-lobed cam.
  • To screw the implant fixture, it is possible to use the ratchet with big insert P800000,  using the manual screwdrivers for three-lobed camP 600008 long, and P600011 short.
  • The cam screwdrivers have dot markings used as references for directing the cams of the implant while screwing. This should be useful when applying the prosthesis, if we are using an angled abutment.
  • Recommended screwing speed: 15/20 rpm.
  • Torque not exceeding 40 Ncm.
  • No irrigation.
  • We recommend removing the cap screw from its housing and screwing it onto the implant using the manual screwdriver with no torque control  P500005/ P600000, to have direct perception of correct positioning of the screw and of its screwing.

 

Content of the pack:
- Threaded implant Grade 4 Ti
- Mounter Grade 5 Ti
- Cap screw Grade 2 Ti
CODEPRODUCT NAMEDIAMETER MMLENGHTCOLOR CODEIVA
P103785FIXTURE3.758.5yellow4%
P103710FIXTURE3.759.95yellow4%
P103711FIXTURE3.7511yellow4%
P103713FIXTURE3.7513yellow4%
P103715FIXTURE3.7515yellow4%
P104285FIXTURE4.28.5blue4%
P104210FIXTURE4.29.95blue4%
P104211FIXTURE4.211blue4%
P104213FIXTURE4.213blue4%
P104215FIXTURE4.215blue4%
P104510FIXTURE4.59.95red4%
P104511FIXTURE4.511red4%
P104513FIXTURE4.513red4%
P104515FIXTURE4.515red4%

Sign up for Email

Get a Newsletter from Edierre and learn everything about our events and offers.