PRIMER SR FOUR- LOBED CAM Ø3,75/4,2/4,5...
Pull the implant out using a proper screwdriver, either a manual...
Pull the implant out using a proper screwdriver, either a manual screwdriver or a ISO screwdriver.
Without touching the fixture, put into place and partly screw down, continue screwing with the handpiece or with the ratchet P500002, using the appropriate ISO insert P900000 and the appropriate screwdrivers P500010, long, three-lobed cam, or P500013 short, three-lobed cam.
To screw the implant fixture, it is possible to use the ratchet with big insert P800000, using the manual screwdrivers for three-lobed camP 600010 long, and P600013 short.
The cam screwdrivers have dot markings used as references for directing the cams of the implant while screwing. This should be useful when applying the prosthesis, if we are using an angled abutment.
Recommended screwing speed: 15/20 rpm.
Torque not exceeding 40 Ncm.
No irrigation.
We recommend removing the cap screw from its housing and screwing it onto the implant using the manual screwdriver with no torque control P500005/ P600000, to have direct perception of correct positioning of the screw and of its screwing.
Pull the implant out using a proper screwdriver, either a manual screwdriver or a ISO screwdriver.
Without touching the fixture, put into place and partly screw down, continue screwing with the handpiece or with the ratchet P500002, using the appropriate ISO insert P900000 and the appropriate screwdrivers P500010, long, three-lobed cam, or P500013 short, three-lobed cam.
To screw the implant fixture, it is possible to use the ratchet with big insert P800000, using the manual screwdrivers for three-lobed camP 600010 long, and P600013 short.
The cam screwdrivers have dot markings used as references for directing the cams of the implant while screwing. This should be useful when applying the prosthesis, if we are using an angled abutment.
Recommended screwing speed: 15/20 rpm.
Torque not exceeding 40 Ncm.
No irrigation.
We recommend removing the cap screw from its housing and screwing it onto the implant using the manual screwdriver with no torque control P500005/ P600000, to have direct perception of correct positioning of the screw and of its screwing.
CODE | PRODUCT NAME | DIAMETER MM | LENGHT | COLOR CODE | IVA |
---|---|---|---|---|---|
P103310 | FIXTURE | 3.3 | 9.95 | grey | 4% |
P103311 | FIXTURE | 3.3 | 11 | grey | 4% |
P103313 | FIXTURE | 3.3 | 13 | grey | 4% |
P103315 | FIXTURE | 3.3 | 15 | grey | 4% |
Get a Newsletter from Edierre and learn everything about our events and offers.