PRIMER SHORT FOUR-LOBED CAM  Ø 4.8

PRIMER SHORT FOUR-LOBED CAM Ø 4.8 | dental surgery swicht platform

PRIMER SHORT FOUR-LOBED CAM Ø 4.8
Ask
Print
Invite a Friend

PRIMER SHORT FOUR-LOBED CAM Ø 4.8

Pull the implant out using a proper screwdriver, either a manual screwdriver or a ISO screwdriver.
  • Pull the implant out using a proper screwdriver, either a manual screwdriver or a ISO screwdriver.
  • Without touching the fixture, put into place and partly screw down. Continue screwing with the handpiece or with the ratchet P500002 using the appropriate ISO insert P900000 and the appropriate screwdrivers:  P500008, long, four-lobed cam, or P500011 short, four-lobed cam.
  • To screw the implant fixture, it is possible to use the ratchet with big insert, P800000, using the manual screwdrivers for four-lobed cam, P600008 long and P600011 short
  • The cam screwdrivers have dot markings used as references for directing the cams of the implant while screwing. This should be useful when applying the prosthesis, if we are using an angled abutment.
  • Recommended screwing speed: 15/20 rpm
  • Torque not exceeding 40 Ncm.
  • No irrigation.
  • We recommend removing the cap screw from its housing and screwing it onto the implant using the manual screwdriver with no torque control, item P 500005 / item P 600000 to feel directly correct positioning of the screw and how it is screwed in.

 

  • Pull the implant out using a proper screwdriver, either a manual screwdriver or a ISO screwdriver.
  • Without touching the fixture, put into place and partly screw down. Continue screwing with the handpiece or with the ratchet P500002 using the appropriate ISO insert P900000 and the appropriate screwdrivers:  P500008, long, four-lobed cam, or P500011 short, four-lobed cam.
  • To screw the implant fixture, it is possible to use the ratchet with big insert, P800000, using the manual screwdrivers for four-lobed cam, P600008 long and P600011 short
  • The cam screwdrivers have dot markings used as references for directing the cams of the implant while screwing. This should be useful when applying the prosthesis, if we are using an angled abutment.
  • Recommended screwing speed: 15/20 rpm
  • Torque not exceeding 40 Ncm.
  • No irrigation.
  • We recommend removing the cap screw from its housing and screwing it onto the implant using the manual screwdriver with no torque control, item P 500005 / item P 600000 to feel directly correct positioning of the screw and how it is screwed in.

 

Content of the pack:
- Threaded implant Grade 4 Ti
- Mounter Grade 5 Ti
- Cap screw Grade 2 Ti
CODEPRODUCT NAMEDIAMETER IN MMLENGHTCOLOR CODEIVA
P104866SHORT FIXTURE4.86.6white4